The AstralPool ICI Gas Heater marks the launch of our Next Generation line of gas heaters. It offers flexibility with options for Natural or LPG gas, and is available in 200MJ/h and 400MJ/h sizes for both indoor and outdoor settings.
Crucially, the ICI is the sole full-modulating mid-efficiency heater on the market. This unique capability allows the heater to finely control and steady the heat output, which contributes to increased product longevity and reduced service expenses. Installation is straightforward, thanks to factory-fitted standard AstralPool connections. Furthermore, it easily integrates with the AstralPool Viron Connect automation system, giving you complete remote temperature control.
The AstralPool ICI-400B Gas Heater introduces our Next Generation gas heating range. It is available in a 400MJ/h size for both indoor and outdoor models and can operate on either Natural or LPG gas, suiting diverse pool owners’ requirements. The ICI-400B is uniquely the only full-modulating mid-efficiency heater on the market and is factory-fitted with standard 2 PVC AstralPool connections for easy installation.
The ICI incorporates an integrated bypass feature that enables low water-flow operation, contributing to reduced water usage.
This entirely new burner was designed and built in Canada specifically for our ICI and Viron eVo heaters. It utilizes a special woven mesh originating from the aerospace industry and has undergone thousands of hours of testing with significantly improved results.
We have streamlined the engineering of the ICI by reducing the number of internal components. This simplification ensures both easier servicing and simplified installation procedures.
| Product | 400B MJ/h | ICI-400B Heater |
|---|---|---|
| Code | ||
| Technology | ||
| Gas Connection | AS/NZ 5601 | |
| Gas Usage Rate of Nominal Rate (%) | +/- 5 | |
| Natural Gas Inlet Static Gas Pressure (kPa) | 1.13 – 5 | |
| LPG Inlet Static Gas Pressure (kPa) | 2.75 – 5 | |
| Natural Gas Inlet Operating Pressure-High Fire (kPa) | 1.13 | |
| LPG Gas Inlet Operating Pressure-High Fire (kPa) | 2.75 | |
| Water Flow Rate (L/min) | 200 – 500 | |
| Water pH | 7.6 – 7.8 | |
| Water Total Alkalinity (p.p.m) | 80 – 120 | |
| Water Calcium Hardness (p.p.m) | 150 – 250 | |
| Water Salinity (p.p.m) | 4000 max. | |
| Chlorine Max. Content (p.p.m) | 3 | |
| Bromine Max. Content (p.p.m) | 5 | |
| NG – CO Level (p.p.m) | 30 – 60 | |
| LPG – CO Level (p.p.m) | 50 – 150 | |